Picture depicts mill on left side and primary
clarifier on right side. The four cell aeration basin is in the
middle with the two secondary clarifiers to its right.
|
| PROJECT: MECHANICAL PULP AND PAPER MILL
EFFLUENT TREATMENT PLANT |
| LOCATION: Port Alberni, B.C. |
| OWNER: MacMillan Bloedel Limited |
| DESCRIPTION: Effluent from a
groundwood / BCTMP / paper machine mill with a flow of 85,000
m3/d and a BOD load of 20 t/d is treated by a five
cell activated sludge plant allowing parallel, series or mixed
flow modes. The treatment process also includes pH adjustment,
primary clarification, nutrient addition, two 1,750 HP single
stage centrifugal blowers for aeration, rotary screen sludge
thickeners, sludge screw presses and DCS control. |
| ROLE: Specialist subconsultant,
pre-design, process design, equipment specification and selection,
supervisor training and start-up assistance. |